    Poiseuille Flow Calculator

    Blood through a 10 cm vessel of 2 mm radius with a 100 Pa pressure drop flows at 1.7952 mL/s, from Poiseuille’s law.

    Solve for:
    Show flow rate in:

    Blood about 3–4 mPa·s, water at 20 °C 1.0 mPa·s.

    Flow rate Q =

    1.79519580205131 mL/s

    Full answer, then cut to fewer decimals (not rounded):

    • 1.79519580205131 mL/s
    • 1.7951958020513 mL/s
    • 1.795195802051 mL/s
    • 1.79519580205 mL/s
    • 1.7951958020 mL/s
    • 1.795195802 mL/s
    • 1.79519580 mL/s
    • 1.7951958 mL/s
    • 1.795195 mL/s
    • 1.79519 mL/s
    • 1.7951 mL/s
    • 1.795 mL/s
    • 1.79 mL/s
    • 1.7 mL/s
    In m³/s
    0.000001795195802 m³/s
    In mL/min
    107.7117481 mL/min
    In L/min
    0.1077117481 L/min
    Hydraulic resistance 8μL/(πr⁴)
    55704230.08 Pa·s/m³
    Mean velocity Q/(πr²)
    14.28571429 cm/s
    Radius effect
    halving r cuts flow 16-fold at the same ΔP
    Step-by-step solution
    1. Convert units: r = 2 mm = 0.002 m; μ = 3.5 mPa·s = 0.0035 Pa·s; L = 10 cm = 0.1 m
    2. Q = π × r⁴ × ΔP ÷ (8 × μ × L)
    3. Q = π × 0.002⁴ × 100 ÷ (8 × 0.0035 × 0.1)
    4. Q = 0.000001795195802 m³/s = 1.795195802 mL/s

    Poiseuille Flow Formula

    Q = π r⁴ ΔP / (8 μ L)

    resistance R = 8μL/(πr⁴); valid for steady laminar flow of a Newtonian fluid

    Worked Example

    Blood (3.5 mPa·s) through a 2 mm radius, 10 cm vessel with 100 Pa pressure difference:

    1. Convert units: r = 2 mm = 0.002 m; μ = 3.5 mPa·s = 0.0035 Pa·s; L = 10 cm = 0.1 m
    2. Q = π × r⁴ × ΔP ÷ (8 × μ × L)
    3. Q = π × 0.002⁴ × 100 ÷ (8 × 0.0035 × 0.1)
    4. Q = 0.000001795195802 m³/s = 1.795195802 mL/s

    In mL/min: 107.7117481 mL/min · In L/min: 0.1077117481 L/min · Hydraulic resistance 8μL/(πr⁴): 55704230.08 Pa·s/m³ · Mean velocity Q/(πr²): 14.28571429 cm/s · Radius effect: halving r cuts flow 16-fold at the same ΔP

    GATE tip

    Vessel resistances combine like electrical ones: in series they add, in parallel the reciprocals add. Check the Reynolds number (below about 2000) to confirm laminar flow.

    More Bioinstrumentation and Physiology Calculators

    Frequently asked questions

    Why does radius matter so much?

    Flow scales with r⁴: narrowing a vessel by 16 % halves the flow at the same pressure, which is why small changes in arteriole radius control blood flow.

    Is blood Newtonian?

    Not exactly: its viscosity falls at high shear rates and depends on haematocrit. Poiseuille’s law is a good first estimate in larger vessels.

    Sources

    Last reviewed: . Factors are stored exactly and computed with 50-digit decimal arithmetic. See how we verify conversion factors.

    Cite this page

    APA

    Scientific Converters. (2026, October 15). Poiseuille Flow Calculator. Retrieved October 25, 2026, from https://scientificconverters.com/calculators/poiseuille-flow-calculator/

    IEEE

    Scientific Converters, "Poiseuille Flow Calculator," scientificconverters.com. Accessed: Oct. 25, 2026. [Online]. Available: https://scientificconverters.com/calculators/poiseuille-flow-calculator/

    Send feedback

    Found a wrong value, a missing unit or an idea? Tell us. We read every message.

    What is it about?

    We store your message, the page you were on and your email if given. See the privacy policy.