Reverberation Time Calculator
A 1000 m³ hall whose surfaces provide 94 m² of absorption has a Sabine reverberation time of 1.71277 s.
One area per surface type: floor, ceiling, walls, seats…
1.71276595744681 s
Full answer, then cut to fewer decimals (not rounded):
- 1.71276595744681 s
- 1.7127659574468 s
- 1.712765957446 s
- 1.71276595744 s
- 1.7127659574 s
- 1.712765957 s
- 1.71276595 s
- 1.7127659 s
- 1.712765 s
- 1.71276 s
- 1.7127 s
- 1.712 s
- 1.71 s
- 1.7 s
- Total absorption A = ΣSα
- 94 m² sabins
- Mean absorption coefficient
- 0.1342857143
- Eyring T₆₀
- 1.595003075 s
Step-by-step solution
- A = ΣSα = 200 × 0.02 + 200 × 0.3 + 300 × 0.1 = 94 m²
- T = 0.161 V / A = 0.161 × 1000 ÷ 94 = 1.712765957 s
Reverberation Time Formula
T₆₀ = 0.161 V / ΣSα
Eyring: T = 0.161 V / (−S ln(1 − ᾱ))
Worked Example
A 1000 m³ hall with 200, 200 and 300 m² of surfaces at α = 0.02, 0.3 and 0.1:
- A = ΣSα = 200 × 0.02 + 200 × 0.3 + 300 × 0.1 = 94 m²
- T = 0.161 V / A = 0.161 × 1000 ÷ 94 = 1.712765957 s
Mean absorption coefficient: 0.1342857143 · Eyring T₆₀: 1.595003075 s
GATE tip
In imperial units Sabine’s constant is 0.049 (ft³, ft²); use 0.161 only with metres.
More Building Physics and Services Calculators
-
U-Value Calculator
U = 1 / (R_si + Σ d/λ + R_so)
R_si = 0.13, R_so = 0.04 m²·K/W for walls (ISO 6946)
Example: A 230 mm brick wall plastered 20 mm on both faces: U-value = 1.96268 W/(m²·K).
-
Lumen Method Calculator
N = E A / (F n UF MF)
room index K = LW / (Hm(L + W))
Example: A 10 × 8 m office lit to 300 lux with twin 3000 lm luminaires, UF 0.6 and MF 0.8: Number of luminaires N = 8.33333.
-
Air Changes per Hour Calculator
Q = ACH × V
Q in m³/h, V room volume in m³
Example: A 6 × 5 × 3 m room at 6 air changes per hour: Airflow = 540 m³/h.
-
Solar Angle Calculator
sin α = sin φ sin δ + cos φ cos δ cos h
δ = 23.45 sin(360(284 + n)/365); h = 15° × (t − 12)
Example: Latitude 23° N at solar noon on 21 June: Solar altitude α = 89.5502 °.
Frequently asked questions
What reverberation time is ideal?
Speech rooms about 0.6–1.0 s; music halls 1.5–2.2 s, rising with volume.
When is Eyring better than Sabine?
For absorbent rooms (mean α above about 0.2), where Sabine overestimates the decay time.
Sources
- The International System of Units (SI), 9th edition (SI Brochure), Bureau International des Poids et Mesures .
Last reviewed: . Factors are stored exactly and computed with 50-digit decimal arithmetic. See how we verify conversion factors.
Cite this page
APA
Scientific Converters. (2026, October 15). Reverberation Time Calculator. Retrieved October 29, 2026, from https://scientificconverters.com/calculators/reverberation-time-calculator/
IEEE