Minimum Reflux Ratio Calculator
A saturated-liquid feed of 50 % with α = 2.5, distilled to 95 %, has a minimum reflux ratio of 1.1.
1.1
- Underwood root θ
- 1.428571429
- Typical operating reflux 1.2–1.5 R_min
- 1.65
Step-by-step solution
- Solve αx_F/(α − θ) + (1 − x_F)/(1 − θ) = 1 − q for 1 < θ < α → θ = 1.428571429
- R_min + 1 = αx_D/(α − θ) + (1 − x_D)/(1 − θ) → R_min = 1.1
Minimum Reflux Ratio Formula
Σ αxF/(α − θ) = 1 − q; R_min + 1 = Σ αxD/(α − θ)
saturated liquid feed (q = 1): R_min = [x_D/x_F − α(1 − x_D)/(1 − x_F)]/(α − 1)
Worked Example
A saturated-liquid feed at 50 % with α = 2.5 and 95 % distillate:
- Solve αx_F/(α − θ) + (1 − x_F)/(1 − θ) = 1 − q for 1 < θ < α → θ = 1.428571429
- R_min + 1 = αx_D/(α − θ) + (1 − x_D)/(1 − θ) → R_min = 1.1
Typical operating reflux 1.2–1.5 R_min: 1.65
GATE tip
For a saturated liquid feed, the pinch is at x = x_F: R_min = (x_D − y*)/(y* − x_F) with y* from the equilibrium curve.
More Mass Transfer Calculators
-
Fenske Equation Calculator
N_min = ln[(x_D/(1 − x_D))((1 − x_B)/x_B)] / ln α
N_min includes the reboiler as a stage
Example: Separating to 95 % and 5 % with α = 2.5: Minimum number of stages N_min = 6.42687.
-
Kremser Equation Calculator
N = ln[((y_N+1 − mx₀)/(y₁ − mx₀))(1 − 1/A) + 1/A] / ln A
A = L/(mV); N = (y_N+1 − y₁)/(y₁ − mx₀) when A = 1
Example: Absorbing a gas from 5 % to 0.5 % with pure solvent, m = 1.2 and L/V = 1.8: Number of ideal stages N = 3.41902.
-
Fick’s Law Calculator
N_A = (D_AB P / RTz) ln[(P − p_A2)/(P − p_A1)]
equimolar: N_A = D_AB (p_A1 − p_A2)/(RTz)
Example: Water evaporating at 25 °C through 10 mm of still air (D = 0.26 cm²/s): Molar flux N_A = 0.00337961 mol/(m²·s).
-
Evaporator Calculator
S λ_s = F c_p (T₁ − T_F) + V λ
P = F x_F/x_P, V = F − P, economy = V/S, A = Q/(U ΔT)
Example: 10,000 kg/h of 5 % solution fed at 25 °C, concentrated to 25 % at 100 °C with 120 °C steam: Steam required S = 9562.22 kg/h.
Frequently asked questions
What does q mean?
The fraction of feed that is liquid (moles of liquid added to the stripping section per mole of feed): 1 for saturated liquid, 0 for saturated vapour.
What reflux is used in practice?
Usually 1.2 to 1.5 times R_min, balancing column height against reboiler and condenser duty.
Sources
- The International System of Units (SI), 9th edition (SI Brochure), Bureau International des Poids et Mesures .
Last reviewed: . Factors are stored exactly and computed with 50-digit decimal arithmetic. See how we verify conversion factors.
Cite this page
APA
Scientific Converters. (2026, October 15). Minimum Reflux Ratio Calculator. Retrieved October 29, 2026, from https://scientificconverters.com/calculators/minimum-reflux-ratio-calculator/
IEEE
Scientific Converters, "Minimum Reflux Ratio Calculator," scientificconverters.com. Accessed: Oct. 29, 2026. [Online]. Available: https://scientificconverters.com/calculators/minimum-reflux-ratio-calculator/