Fenske Equation Calculator
Taking a binary from 5 % to 95 % purity with α = 2.5 needs 6.42687 theoretical stages at total reflux.
Use the geometric mean of top and bottom values if α varies.
6.42686622649553
Full answer, then cut to fewer decimals (not rounded):
- 6.42686622649553
- 6.4268662264955
- 6.426866226495
- 6.42686622649
- 6.4268662264
- 6.426866226
- 6.42686622
- 6.4268662
- 6.426866
- 6.42686
- 6.4268
- 6.426
- 6.42
- 6.4
- Minimum theoretical plates (excluding the reboiler)
- 5.426866226
Step-by-step solution
- N_min = ln[(x_D/(1 − x_D)) × ((1 − x_B)/x_B)] / ln α
- N_min = ln[(0.95/0.05) × (0.95/0.05)] ÷ ln 2.5 = 6.426866226
Fenske Equation Formula
N_min = ln[(x_D/(1 − x_D))((1 − x_B)/x_B)] / ln α
N_min includes the reboiler as a stage
Worked Example
Separating to 95 % and 5 % with α = 2.5:
- N_min = ln[(x_D/(1 − x_D)) × ((1 − x_B)/x_B)] / ln α
- N_min = ln[(0.95/0.05) × (0.95/0.05)] ÷ ln 2.5 = 6.426866226
GATE tip
Fenske gives N_min, Underwood gives R_min, and Gilliland links them to the actual stages at the chosen reflux.
More Mass Transfer Calculators
-
Minimum Reflux Ratio Calculator
Σ αxF/(α − θ) = 1 − q; R_min + 1 = Σ αxD/(α − θ)
saturated liquid feed (q = 1): R_min = [x_D/x_F − α(1 − x_D)/(1 − x_F)]/(α − 1)
Example: A saturated-liquid feed at 50 % with α = 2.5 and 95 % distillate: Minimum reflux ratio R_min = 1.1.
-
Kremser Equation Calculator
N = ln[((y_N+1 − mx₀)/(y₁ − mx₀))(1 − 1/A) + 1/A] / ln A
A = L/(mV); N = (y_N+1 − y₁)/(y₁ − mx₀) when A = 1
Example: Absorbing a gas from 5 % to 0.5 % with pure solvent, m = 1.2 and L/V = 1.8: Number of ideal stages N = 3.41902.
-
Fick’s Law Calculator
N_A = (D_AB P / RTz) ln[(P − p_A2)/(P − p_A1)]
equimolar: N_A = D_AB (p_A1 − p_A2)/(RTz)
Example: Water evaporating at 25 °C through 10 mm of still air (D = 0.26 cm²/s): Molar flux N_A = 0.00337961 mol/(m²·s).
-
Evaporator Calculator
S λ_s = F c_p (T₁ − T_F) + V λ
P = F x_F/x_P, V = F − P, economy = V/S, A = Q/(U ΔT)
Example: 10,000 kg/h of 5 % solution fed at 25 °C, concentrated to 25 % at 100 °C with 120 °C steam: Steam required S = 9562.22 kg/h.
Frequently asked questions
Is the reboiler counted in N_min?
Yes: Fenske’s N_min counts the partial reboiler as a stage, so the column needs N_min − 1 plates.
Which α should be used?
The geometric mean of the top and bottom values, √(α_top α_bottom), when α varies along the column.
Sources
- The International System of Units (SI), 9th edition (SI Brochure), Bureau International des Poids et Mesures .
Last reviewed: . Factors are stored exactly and computed with 50-digit decimal arithmetic. See how we verify conversion factors.