Scientific Converters Precise unit conversions for science & engineering.

    Loading…

    Webster Signal Design Calculator

    A two-phase signal with critical flows of 500 and 600 PCU/h (saturation 1800 PCU/h) and 12 s lost time needs an optimum cycle of 59.1429 s.

    Typically 2 s start-up lost time plus all-red per phase.

    Optimum cycle length C₀ =

    59.1428571428572 s

    Full answer, then cut to fewer decimals (not rounded):

    • 59.1428571428572 s
    • 59.142857142857 s
    • 59.14285714285 s
    • 59.1428571428 s
    • 59.142857142 s
    • 59.14285714 s
    • 59.1428571 s
    • 59.142857 s
    • 59.14285 s
    • 59.1428 s
    • 59.142 s
    • 59.14 s
    • 59.1 s
    Y = Σ y
    0.6111111111
    Effective green available C₀ − L
    47.14285714 s
    Green time split
    Phasey = q/sEffective green (s)
    10.27777821.4286
    20.33333325.7143
    Step-by-step solution
    1. y = q/s for each phase: 0.277778, 0.333333
    2. C₀ = (1.5L + 5) / (1 − Y) = (1.5 × 12 + 5) ÷ (1 − 0.6111111111) = 59.14285714 s

    Webster Signal Design Formula

    C₀ = (1.5L + 5) / (1 − Y)

    Y = Σ q/s over critical phases; green gᵢ = (C₀ − L) yᵢ/Y

    Worked Example

    A two-phase signal with critical flows of 500 and 600 PCU/h, saturation flow 1800 PCU/h and 12 s lost time:

    1. y = q/s for each phase: 0.277778, 0.333333
    2. C₀ = (1.5L + 5) / (1 − Y) = (1.5 × 12 + 5) ÷ (1 − 0.6111111111) = 59.14285714 s

    Effective green available C₀ − L: 47.14285714 s

    Green time split
    Phasey = q/sEffective green (s)
    10.27777821.4286
    20.33333325.7143

    GATE tip

    Round the cycle up to the next 5 s in practice, but give the unrounded C₀ in a NAT answer.

    More Transportation Engineering Calculators

    Frequently asked questions

    What happens when Y approaches 1?

    The cycle length grows without limit: the junction is near saturation and needs more capacity, not longer cycles.

    Is the computed green time the displayed green?

    It is effective green; displayed green = effective green + lost time − amber, per phase.

    Sources

    Last reviewed: . Factors are stored exactly and computed with 50-digit decimal arithmetic. See how we verify conversion factors.

    Cite this page

    APA

    Scientific Converters. (2026, October 15). Webster Signal Design Calculator. Retrieved October 29, 2026, from https://scientificconverters.com/calculators/webster-signal-calculator/

    IEEE

    Scientific Converters, "Webster Signal Design Calculator," scientificconverters.com. Accessed: Oct. 29, 2026. [Online]. Available: https://scientificconverters.com/calculators/webster-signal-calculator/

    Send feedback

    Found a wrong value, a missing unit or an idea? Tell us. We read every message.

    What is it about?

    We store your message, the page you were on and your email if given. See the privacy policy.